Generac®/Briggs & Stratton® Transfer Switch Conversion to 2 Wire Start
KGC-1 Transfer Switch Convertor

KGC-1

240 VAC Sensing ATS to 2-Wire Start Converter

The KGC-1 converts a 240V sensing transfer switch to a 2 wire start transfer switch.

The interface provides the necessary voltage sensing, timing functions and switching circuits required for automatic operation. This allows a 2 wire start generator to be installed without having to change the transfer switch or wiring between the transfer switch and generator.

  • Allows any 2-wire start generator to be installed without having to change the transfer switch or wiring between the transfer switch and generator.
  • Provides the necessary voltage sensing, timing functions and switching circuits required for automatic operation
  • Works with Generac® and Briggs & Stratton® transfer switches
  • Utility loss timer selectable 5 seconds or 30 seconds
  • Generator cool-down: 10 seconds, 300 seconds, or 600 seconds
  • Utility return transfer timer selectable between 30 seconds, 129 seconds, or 600 seconds
  • LED lights to indicate utility mode, generator mode, and transfer
  • 3-phase models available  – consult factory
  • 2 year warranty

Add-On Items

  • Weekly exercise timer – Item# DTS-1